- 1-STAGE, PILOT OPERATED TYPE
- 24 VOLT AC AT 50/60 HERTZ INPUT SUPPLY RATING
- UL, CSA APPLICABLE STANDARD
- RESIDENTIAL FURNACE, ROOF-TOP FURNACE, RESIDENTIAL BOILER, UNIT HEATER, INFRARED HEATER, SPACE HEATER AND COMMERCIAL COOKING UNIT APPLICATION
- -40 TO 175 DEG F TEMPERATURE RATING
- NATURAL TO LP CONVERSION KIT, EXTENSION HARNESS INCLUSIONS/FEATURES
- 1/2 PSI PRESSURE RATING
- VERTICAL MOUNTING DETAILS
- GAS MEDIA HANDLED
- 1/2 INCH THREADED X 1/2 INCH THREADED PORT CONNECTION
- FUEL TYPE NATURAL
- OVERALL DIMENSION 4.1 INCH LENGTH X 3.2 INCH WIDTH X 4.9 INCH HEIGHT
- PRESSURE TAPPING 1/8 INCH THREADED
- IGNITION TYPE INTERMITTENT
Gas Fired Appliances Including Residential Furnace, Roof Top Furnace, Residential Boiler, Unit Heater, Infrared Heater, Space Heater and Commercial Cooking Unit
CSA
1.6 Second at 3 Micro Amp
2-Rod
Natural Gas
Continuous Retry
Pilot
90 Second
08526779109
4.1 Inch Length x 3.2 Inch Width x 4.9 Inch Height
-40 to 175 Deg F
Standard Opening, Straight Through, Intermittent Hot Surface Pilot Ignition
085267791090